          220kV three-phase oil-immersed power transformers

          Overview

          The company 220 kv transformer, the use of the French areva analysis software and the company special computer and validation procedures, for transformer core, coil, machine body, lead, tank etc all-round optimization design and verification, to ensure that product performance. Superior technology and equipment, the careful material selection and efficient production, makeds the transformer has small volume, light weight, low loss, low partial discharge, low noise characteristics, the product quality is superior, energy conservation and environmental protection, easy installtion and maintenance, reliable operation and stable, reliable, economic and environmental characteristics, suitable for power plants, substations, large industrial and mining petrochemical enterprise, etc.

          • Execution standard
          • Model
          • Performance
          • Parameters
          • Appearance
            • 1GB1094、1~2-1996 power transformers
            • 2GB1094、3、5-2003 power transformers
            • 3GB6451-2008 three-phase oil-immersed power transformers technical parameters and needs
          • Performance characteristics
            • Low loss: no-load loss than the national standard GB6454-1999 fell by 40% or so, load loss than the national standard GB6451-1999 down 15%;
            • Low noise: noise level to reach 60 db below, than the national standards generally drop nearly 20 db. Users have special requirements, but also special design and manufacture (55 db below), satisfy the our country city residents power supply and demand;
            • Beautiful shape: the tank bending corrugated structure, shot-blasting, powder electric spray paint, wide blade plate radiator, swimming do not fade.
            • Low bureau put: 220 kv all the product process are clean homework, implement body internal metal parts, insulating parts all round turn, bureau in 70 PC y109.52 to control the following;
            • Anti-short circuit ability: the company to design and manufacture of SFP10-200000/220 transformer already through national transformer for quality supervision and inspection center short circuit capacity test.
            • No leakage: all seal seam allowance limit, upper and lower box along the double sealing, sealers import. Promise never leakage.
          • SFP10/220 kVthree-phase double winding no excitation voltage powertransformer technology parameters
            Rate volume (kVA) Rated voltage (kV) Vector group No-load loss (kW) On-load loss (kW) Excit. Curr. (%) Impedance (%)
            High voltage (kV) Low voltage (kV)
            31500 220±2×2.5%
            242±2×2.5%
            6.3 YNd11 26128 0.3 12-14
            400006.631149
            5000010.536178
            6300011412080.2
            7500010.547237
            900001150272
            120000 11
            13.8
            15.75
            18
            20
            61327
            15000083380
            160000854000.15
            18000090436
            240000105520
            30000015.75140620
            36000018160700
            37000020168720
            400000180770
            420000185800

            SFPS10/220kV low pressure 66kV level three-phase double-winding non-excitation regulator power transformers technical parameters
            Rate volume (kVA) Rated voltage (kV) Vector group No-load loss (kW) On-load loss (kW) Excit. Curr. (%) Impedance (%)
            High voltage (kV) Low voltage (kV)
            31500 220±2×2.5%
            242±2×2.5%
            63
            66
            69
            YNd11 29143 0.312-14
            4000034167
            5000040200
            63000472340.2
            9000055305
            12000070365
            15000085428
            180000904850.15
            240000110600

            SFZ10/220kV three-phase , two-winding OLTC power transformer technical parameters
            Rate volume (kVA) Rated voltage (kV) Vector group No-load loss (kW) On-load loss (kW) Excit. Curr. (%) Impedance (%)
            High voltage (kV) Low voltage (kV)
            31500 220±8×1.25% 6.3、6.6
            10.5、11
            35、37
            38.5
            YNd11 25128 0.312-14
            4000032148
            5000035179
            63000452080.2
            90000 10.5、11
            35、37
            38.5
            55272
            12000069327
            15000080383
            180000904420.15
            120000 66 69 703270.2
            15000085388
            180000954500.15

            OSSFP10/220kV three-phase three-winding excitation voltage auto power transformers technical parameters
            Rated volume (kVA) Rated voltage (kV) Vector group Step-up combination Step-down combination No-load current (%) Short-circult impedance (%)
            High voltage (kV) Medium pressure (kV) Lo voltage (kV) No-load loss On-load loss No-load loss On-load loss Step-up Step-down
            31500 220±2×2.5%
            242±2×2.5%
            115
            121
            6.6
            10.5
            11
            35
            37
            38.5
            YNa0d11 191111794 0.3 HV-MV
            12-14

            HV-LV
            8-12

            MV-LV
            14-18
            HV-MV
            8-10

            HV-LV
            28-34

            MV-LV
            18-24
            400002213620114
            500002616123136
            6300030190271620.2
            900003825534221
            12000010.5、11
            13.8、
            15.75
            18、35
            37、38.5
            4732142272
            1500005538349323
            18000062438563660.15
            2400007456367476

            SSFP10/220kV three-phase three-winding excitation voltage power transformers technical parameters
            Rated volume (kVA) Rated voltage Vector group No-load loss (kW) On-load loss (kW) No-load current (%) Short-circult impedance (%)
            High voltage (kV) Medium pressure (kV) Low voltage (kV) Step-up Step-down
            31500 220±2×2.5%
            242±2×2.5%
            69
            125
            121
            6.3
            6.6
            10.5
            11
            35
            37
            38.5
            YNyn0d11 30153 0.3 HV-MV
            22-24

            HV-LV
            12-14

            MV-LV
            7-9
            HV-MV
            12-14

            HV-LV
            22-24

            MV-LV
            7-9
            4000036178
            5000042212
            63000462380.2
            9000010.5、11
            13.8、35
            37、36.5
            55322
            12000069408
            15000011
            13.8
            15.75
            35
            37
            38.5
            80465
            180000905000.15
            240000120630
            300000140750

            SSFPZ10/220kV three-phase three-winding power transformer load tap technical parameters
            Rated volume (kVA) Rated voltage Vector group No-load loss (kW) On-load loss (kW) No-load current (%) Capacity allocation (%) Short-circult impedance (%)
            High voltage (kV) Medium pressure (kV) Low voltage (kV)
            31500 220±8×1.25% 69
            115
            121
            6.3、6.6
            10.5、11
            35、37 38.5
            YNyn0d11 32153 0.3 100/100/100
            100/50/100
            100/100/50
            HV-MV
            12-14

            HV-LV
            22-24

            MV-LV
            7-9
            4000038178
            5000045210
            63000502410.2
            9000010.5
            11
            13.8
            35
            37
            36.5
            59318
            12000070410
            15000080465
            180000905500.15
            240000115690

            OSSFPZ10/220 kVthree-phase three-winding power transformer OLTC auto technical parameters
            Rated volume (kVA) Rated voltage Vector group No-load loss (kW) On-load loss (kW) No-load current (%) Capacity allocation (%) Short-circult impedance (%)
            High voltage (kV) Medium pressure (kV) Low voltage (kV)
            31500 220±8×1.25% 115
            121
            6.3、6.6
            10.5、11
            35、37 38.5
            YNan0d11 20102 0.3 100/100/50 HV-MV
            8-10

            HV-LV
            28-34

            MV-LV
            18-24
            4000023125
            5000027148
            63000321780.2
            90000 10.5
            11
            35
            37
            36.5
            39230
            12000045280
            15000052322
            180000563450.15
            24000062450
          • Null
          No.218, Wusong Road, Shanghai, China [sales headquarters] 200080 400-080-1921
          F12, Shanghai Baokuang International BM Building
          Address: No.666, Zhangwengmiao Road, Fengxian District, Shanghai Postal code:201400
          Switchboard: 86-21-68866111 Fax:86-21-68860333
          ©2013 Shanghai Transformer Work Co., Ltd.
          av在线不卡中文网-半夜他强行挺进了我的体内-成年无码av片